Ambu® AuraGain™ Disposable Laryngeal Mask
AuraGain is the only anatomically curved SGA with integrated gastric access and intubation capability, taking patient safety and airway management efficiency to a new level.
Key Benefits
Learn more about the Ambu AuraGain
Gastric access through an AuraGain
General information
The AuraGain is Ambu’s 2nd generation laryngeal mask, satisfying 3 fundamental airway management needs by integrating gastric access and intubation capability in an anatomically curved single-use device that facilitates rapid establishment of a safe airway.
Rapid placement
The original anatomical curve is pre-formed to follow the anatomy of the human airway, and the soft rounded curve of the AuraGain ensures rapid placement and guarantees long-term performance.
High seal pressure
The thin and soft cuff of the AuraGain is designed to deliver high seal pressures - documented up to 40 cm H2O.*
* Data on file
Gastric control
The integrated gastric access channel is designed with a low friction inner surface to facilitate easy placement of a gastric tube. Introduce a gastric tube through the device and into the stomach of the patient to enable active and passive management of gastric content, and prevent gastric insufflation.
Integrated intubation capability
The AuraGain provides the added safety feature of intubation capability. This means that in case of an unexpected difficult airway, or a “Cannot Intubate – Cannot mask Ventilate” (CI-CV) situation, where the end-game is to intubate the patient, AuraGain can be used as conduit for direct endotracheal intubation assisted by a flexible scope (such as the Ambu® aScope3).
All-round versatility
Rapid placement, high seal pressure, gastric access, and intubation capability make the AuraGain the obvious and safe choice for every procedure where a laryngeal mask is indicated.
Updated max gastric tube recommendation
Ambu has updated the max gastric tube recommendation printed on the device from 14 Fr to 16 Fr. The version with 14 Fr written on the device is fully compatible with gastric tubes up to 16 Fr.
As we switch to the new version, you may receive both versions. To learn whether a product is of the new version, please refer to the label of the product, where you can find the size recommendation.
Suitable applications
Routine anaesthesia, difficult airway patients, failed intubation, resuscitation, use as a conduit for intubation.
Specifications
Spare parts
There are no spare parts or accessories for this product.Downloads
Brochures (4)
(1022.02 KB - pdf)
(2.19 MB - pdf)
(23.09 MB - pdf)
(812.81 KB - pdf)
Datasheets
(921.96 KB - pdf)
Evidence Compendium
(2.84 MB - pdf)
Instructions for use
(4.03 MB - pdf)
Product Information
(2.64 MB - pdf)
Supplementary Information
(263.5 KB - pdf)
(2.23 MB - pdf)
November 2015
Note: US: Rx only